Lincoln Electric SVM125-A service manual Typical DC Weld Output Voltage Waveform

Models: SVM125-A

1 110
Download 110 pages 23.24 Kb
Page 80
Image 80

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-30

F-30

TROUBLESHOOTING & REPAIR

TYPICAL DC WELD OUTPUT VOLTAGE WAVEFORM

MACHINE LOADED – SELECTOR SWITCH AT MAXIMUM POSITION

CH1

0 volts

20 volts

5 ms

MACHINE LOADED TO 250 AMPS AT 40 VDC

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

CLASSIC II

Page 80
Image 80
Lincoln Electric SVM125-A Typical DC Weld Output Voltage Waveform, Machine Loaded Selector Switch AT Maximum Position