Main
Operation and Installation Manual
Direct Vent Tankless W ater Heater
Models: 305 505 705
Table of Contents
305, 505, 705 Indoor Manual 3
Specifications
Model 305 505 705
WARNING
Safety Behavior and Practices
Safety Definitions
Consumer Safety Information
Safety Features
Description of Operation
Features Available on Temperature Controllers
Operating Instructions
Setting the Temperature
NOTICE
DANGER Hot water can be dangerous, especially for infants or children, the elderly,
NOTICE
Temperature Options Without a Temperature Controller
WARNING DO NOT adjust the other dip
NOTICE
Temperature Ranges
Setting Controller to Mute
Maintenance
Cleaning
Vent System
Motors
Temperature Controller
Error Codes
Error Code Table
Code Fault Remedy
Error Code Table
10 305, 505, 705 Indoor Manual
Code Fault Remedy
Trouble Shooting for Common Issues
Water Quality
Accessing Operating Information
Flushing the Heat Exchanger (Error Code: LC or 00)
Water Heater
Circulating Pump
H2
H1
Installation Instructions
General Instructions
Clearances from Appliance
Attachment of the Water Heater
to side
to floor/ground
to front
Gas Piping
General Instructions
Electrical Connection
Pipe Sizing Procedure - Example
Cubic Feet per Hour (CFH) = Heating Value of Gas (BTU / FT
Gas Piping
Freeze Protection
Water Piping
General Instructions
Pressure Relief Valve
Freeze Protection Piping
KEY
Water Heater
Recommended Piping for Basic Installation
Water Heater
KEY
Recommended Piping for Circulation Systems
GasSupply
KEY
Water Heater
3/4"GasConnection
Optional Piping for Circulation Systems
Minimum 3/4 ColdWater Supply Line
ExpansionTank
BuildingFixtureOutlets
KEY
Venting Instructions
Condensate
Intake / Exhaust Guidelines
Maximum Vent Length
Venting Instructions
Listed and Tested Vent Products for the 305 and 505 Models
Listed and Tested Vent Products for the 705 Model
Venting Products
Vent Manufacturer Contact Information for Installation Instructions and Parts Lists: Heat-Fab
Ubbink
Metal-Fab Inc.
ProTech Systems, Inc.
X
V
AIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTTED
24" V
Additional Clearances - Vent Terminal
VV
V
V
Flue Installation for the 305 and 505 Models
Vertical Termination (condensate collector must be used in all installations)
Horizontal Termination using the Condensate Collector
Horizontal Termination without using the Condensate Collector
Air Intake Assembly
Flue Installation for the 705 Model
6
12 4
12 MIN. ABOVE GRADE OR SNOW LEVEL
Page
High Altitude Installations
Connecting Multiple Water Heaters
Guidelines
WARNING DO NOT adjust the other dip
SwitchNo.
Con t r o l le r s
Temperature Controller Installation
Configurations
Cable Lengths and Size
Location
Temperature Controller Installation
Outline of Remote securing screw 1-21/32" 3-5/16
securing screw
"
wiring hole
Operating Instructions
CLOSE
Manual Valve OPEN
Technical Data
Pressure Drop Curve
Water Flow (gpm)
delta T - Temperature Rise (F)
Outlet Flow Data
Space Heating
Dimensions
L
K
A C D
E G
Ladder Diagram
HOT NEUTRAL
M
CPU
Page