Trouble Shooting for Common Issues

I don’t have any hot water when I open the tap.

Make sure there is gas, water, and electricity to the water heater (power is turned on and the gas is turned on).

When I was using the hot water, the water got cold.

If you adjusted the flow from the tap to lessen it, you may have gone below the minimum flow required. This water heater requires a minimum flow rate to operate. (See the specification page for the flow rate of your model.) Decrease the temperature setting at the temperature controller or increase the water flow.

White smoke comes out of the exhaust.

During colder weather when the exhaust temperature is much hotter than the outside air, the exhaust fumes condense producing water vapor.

When I open a hot tap, I do not immediately get hot water.

Hot water must travel through your plumbing from the water heater to the faucet. The time period for hot water to reach your fixture is determined by the amount of water in the plumbing system between the water heater and the fixture, water pressure, and the flow rate of the fixture.

After I turn off the hot water tap, the fan on the water heater continues to run.

The fan is designed to continue running for a short time after the flow of water stops. This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit.

Accessing Operating Information

To display the most recent error codes press and hold the “On/Off” button for 2 seconds. While holding the “On/ Off” button press the ▲ button. The last 9 error codes will flash one after the other. To exit this mode press the “On/Off” and ▲ button as before.

To display the water flow through the water heater press and hold the ▲ button for 2 seconds and without releasing the ▲ button press the “On/Off” button.

To display the outlet water temperature press and hold the ▼ button for 2 seconds and without releasing the ▼ button press the “On/Off” button.

Water Quality

Consideration of care for your water heater should include evaluation of water quality. If the water quality exceeds the target levels provided in the table, you may want to treat or condition the water.

*Source: Part 143 National Secondary Drinking Water Regulations

 

Maximum Level

 

 

Total Hardness

Up to 200 mg / L

 

 

Aluminum *

Up to 0.2 mg / L

 

 

Chlorides *

Up to 250 mg / L

 

 

Copper *

Up to 1.0 mg / L

 

 

Iron *

Up to 0.3 mg / L

 

 

Manganese *

Up to 0.05 mg / L

 

 

pH *

6.5 to 8.5

 

 

TDS (Total Dissolved

Up to 500 mg / L

Solids) *

 

Zinc *

Up to 5 mg / L

 

 

305, 505, 705 Indoor Manual

11