Clearances from Appliance

 

to Combustibles

to Non-

 

 

Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

305

705

305

705

 

 

505

505

 

 

 

 

 

Top of

6 inches

12 inches

2 inches

2 inches

 

Heater

(152 mm)

(305 mm)

(51 mm)

(51 mm)

 

 

 

 

 

 

 

Back of

0 (zero)

0 (zero)

0 (zero)

0 (zero)

to side

Heater

 

 

 

 

Front of

6 inches

24 inches

6 inches

24 inches

 

Heater

(152 mm)

(610 mm)

(152 mm)

(610 mm)

 

Sides of

2 inches

2 inches

1/2 inch

1/2 inch

 

Heater

(51 mm)

(51 mm)

(13 mm)

(13 mm)

 

Floor/

12 inches

12 inches

12 inches

2 inches

 

Ground

(305 mm)

(305 mm)

(305 mm)

(51 mm)

 

 

 

 

 

 

 

Vent

0 (zero)

4 inches *

0 (zero)

0 (zero)

to floor/ground

 

 

 

 

 

 

 

 

*4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area. The clearance for servicing is 24 inches in front of the water heater.

For closet installation: 305, 505: clearance is 6 inches (152 mm) from the front. 705: clearance is 24 inches (610 mm) from the front.

to top

to front

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

wall installation

brackets

14

305, 505, 705 Indoor Manual

Page 14
Image 14
State Industries U287-084, 705 Series 200 installation manual Clearances from Appliance, Attachment of the Water Heater