Optional Piping for Circulation Systems

NOTE:

For residential and commercial applications, this piping arrangement reduces the warranty to the following:

3 years on heat exchanger

3 year on parts

Full warranty will be maintained if an on-demand recirculation system in incorporated. Refer to the Limited Warranty.

For this application:

Pump should be controlled by an Aquastat, Timer or Combination Aquastat and Timer.

Pump to be sized to maintain circulation loop temperature.

A minimum of 3 GPM flow is recommended for the circulation system.

The pump should be sized to overcome the pressure loss through the water heate r, supply and return plumbing.

Pump to be of bronze or stainless construc - tion.

Note: Water heater outlet temperature cannot be adjusted when circulation pump is running.

Minimum 3/4" Hot Water

Supply Line

Water Heater

Equipment List

QTY

 

 

 

Water Heaters

1

 

Plumbing Installation

1

Kit (Optional)

(3/4" Fittings Include:

2 Unions, 2 Ball Valves,

2 Drain Valves and

1 Pressure Relief Valve.)

3/4" Gas Connection

Gas Supply

Minimum 3/4“ Cold Water Supply Line

(Optional)

2-6 Gallon Storage Tank

(To eliminate cold water sandwich effect caused by frequent On/Off operation)

Expansion Tank

Building Fixture Outlets

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.