DeviceNet Network Scanner DVPDNET-SL

2.3DeviceNet Connection Port

The connector is used on the connection to DeviceNet. Wire by using the connector enclosed with

DVPDNET-SL.

PIN

Signal

Color

Content

 

1

V-

Black

0 VDC

5

2

CAN_L

Blue

Signal-

4

3

SHIELD

-

Shielded

3

2

4

CAN_H

White

Signal+

1

5

V+

Red

24 VDC

 

2.4Address Switch

The switch is used on setting up the node address of DVPDNET-SL on DeviceNet. Range: 00 ~ 63 (64 ~ 99 are forbidden).

Switch setting

Content

 

 

0 … 63

Valid DeviceNet node address

 

 

64…99

Invalid DeviceNet node address

 

 

5

4 3

2

 

1

0

 

4

5

 

3

 

2

 

1

0

 

6

7

8 9

6

7

8 9

Example: If you need to set the node address of DVPDNET-SL to 26, simply switch the corresponding switch of x101 to 2 and the corresponding switch of x100 to 6.

Note:

zPlease set up the node address when the power is switched off. After the setup is completed, re-power

DVPDNET-SL.

zWhen DVPDNET-SL is operating, changing the setting of node address will be invalid.

zUse slotted screwdriver to rotate the switch carefully in case you scratch the switch.

2.5Function Switch

The function switches are for:

„ Setting up the work mode (IN0)

„ Setting up the baud rate of DeviceNet (DR0 ~ DR1)

DR1

DR0

Baud rate

 

 

 

OFF

OFF

125 kbps

OFF

ON

250 kbps

ON

OFF

500 kbps

ON

ON

Incorrect setting

 

ON

When the slave is off-line, the I/O data in

IN0

the buffer area will be held.

 

OFF

When the slave is off-line, the I/O data in

 

 

the buffer area will be cleared.

 

 

IN1

 

Reserved

 

 

 

Note:

zPlease set up the function switch when the power is switched off. After the setup is completed, re-power

6

DVP-PLC Operation Manual

Page 8