Placing the ISDN Order Through Your Telephone Company A-6

Siemens

To order ISDN service for the Siemens® EWSD switch, supply

EWSD

the telephone company with the information provided in

Switch

Table A-5.

Table A-5 Line Configuration for Siemens EWSD

Required Information

Specification

 

 

Line Type

Standard (2B+D) National ISDN-1 line

Line Code

2B1Q

Interface Type

U interface with an RJ-45 jack

Directory Numbers

2*

Circuit-switched Data and Voice

Yes

Bearer Restriction Option

No packet mode data (NOPMD)

Protocol

Functional

SPID Suffix

1

Terminal Endpoint Identifier (TEI)

Dynamic

Key System (EKTS)

No

Flexible Call Offering (FCO)

Yes

*The Directory Number, Circuit-switched Voice, and Circuit-switched Voice Limit parameters should be set to 2 to allow both analog ports to be used simultaneously. Otherwise, if those parameters are set to 1, the ISDN line can only place or receive one call at a time.

FCO (also referred to as Additional Call Offering) allows you to receive an incoming call while a dual-channel Multilink PPP call is active. If you do not want this feature, which may cost extra, FCO is not required.