3Com TECHD-0000000050 manual Rack and Clearance Requirements, Location, Environmental Requirements

Models: TECHD-0000000050

1 32
Download 32 pages 3.95 Kb
Page 14
Image 14
Rack and Clearance Requirements

Rack and Clearance Requirements

Tipping Point recommends that you mount the UnityOne system in a standard 19-or 23-inch rack. The vertical hole spacing on the rack rails must meet standard EIA-310-C requirements, which call for a one inch (2.54 cm) spacing.

Location

The ZPHA should be located near the IPS device in the rack. The device connects to the IPS through the following:

USB cable for power

Network cables (fiber or copper) to receive and transmit network traffic.

When planning the location of the ZPHA, consider the amount of IPS devices you may connect. You can connect up to 5 segments to the ZPHA, depending on the segment components you purchase.

The ZPHA requires only one USB connection for power. The modular ZPHA provides 2 ports (1 type A and 1 type B) on the back panel.

Environmental Requirements

In order for the UnityOne to run properly, your environment must meet the proper criteria.

The following table details the recommendations for temperature, humidity, and altitude settings for the Service Provider (SP) environment.

Table 1 - 1: Environmental Requirements for the UnityOne

Environmental

Description

Specifications

 

 

 

 

 

Temperature

0 to 40 ° C (32 to 104 ° F) — Operating

 

-20 to 80° C (-4 to 176 ° F) — Storage

 

 

Humidity

5 to 95% (non-condensing)

 

 

Altitude

No degradation up to 13K feet above sea level

 

 

Power Requirements

The UnityOne ZPHA receives power through a USB cable connected to the IPS device. The modular ZPHA comes with 1 USB cable. The back panel of the device provides two USB connections (1 type A and 1 type B) , but only one connection is required for proper functioning. You should only attach IPS devices to these USB ports. The ZPHA does not require any other type of power connection to function.

2

UnityOne Modular Fiber/Copper ZPHA Installation Guide V 2.1

Page 14
Image 14
3Com TECHD-0000000050 manual Rack and Clearance Requirements, Location, Environmental Requirements, Power Requirements