Cross-over Cable Installation

You may need to use cross-over and straight cables depending on what two devices are being connected to on a segment. You would use cross-over options typically is you are not connecting to an Ethernet switch.

Internally, the ZPHA is a straight cable, whether in High Availability (HA) or normal mode. If you need a cross-over to connect to the IPS, then you need a cross-over between the ZPHA and the IPS. In other words, the cross-over must stay connected on the IPS side with an additional straight cable when the ZPHA is added.

The following figures display alternate installations of the ZPHA when a cross-over is needed.

Whenever you have a cross-over connection coming in you must use a cross-over cable between the ZPHA and the IPS and a straight cable from the ZPHA to the other device. See Figure 2 - 10, “ZPHA Cross-over Configuration 1:

Figure 2 - 10: ZPHA Cross-over Configuration 1