12 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
Table2 outlines the c onfiguration restrictions.
* This system configuratio n would be supported if y ou replace both of t he older 10BASE-FL modules (3C201400 ) with the newer
10BASE-FL modules (3C20140 0A).

Tabl e 2 Physical Configuration Limitations

System Configuration
Chassis with Revision 8.x
Motherboard
Chassis with Revision 7.x
Motherboard
Chassis with Revision 6.x
Motherboard
2 old 10BASE-FL
modules (3C201400)
1 FDDI (MMF or SMF)
module
1 ATM module
Configuration is not
supported*
Draws 15 amps
Configuration is not
supported*
Draws 14.3 amps
Configuration is not
supported*
Draws 14.45 amps
2 old 10BASE-FL
modules (3C201400)
1 100BASE-FX module
1 ATM module
Configuration is not
supported*
Draws 14.4 amps
Supported configuration Supported configuration
2 old 10BASE-FL
modules (3C201400)
1 100BASE-TX module
1 ATM module
Configuration is not
supported*
Draws 14.6 amps
Supported configuration Configuration is not
supported*
Draws 14.05 amps
2 old 10BASE-FL
modules (3C201400)
1 TP-DDI module
1 ATM module
Configuration is not
supported*
Draws 15.2 amps
Configuration is not
supported*
Draws 14.5 amps
Configuration is not
supported*
Draws 14.65 amps