Special Set-Up Procedure (Continued)
WARNING – Turn off electrical power and disconnect power cord from electrical supply before beginning Special
to personnel could result.
TAPING HEADS
WARNING – Use care when working near knives as knives are extremely sharp. If care is not taken, severe injury to personnel could result.
1.Loosen, but do not remove, the two retaining screws that secure the upper taping head shown in Figure
2.Slide the head forward and lift straight up to remove it from the case sealer.
CAUTION – Taping head weighs approximately 7.2 kg [16 lbs]. Use proper body mechanics when lifting upper or lower taping heads.
3.Lift the lower taping head, shown in Figure
4.Refer to Section II, "Adjustments – Changing Tape Leg Length", page 13 for taping head
Box and Machine Bed Height Range – Refer to Figure
Moving the outer columns up one set of mounting holed increases the maximum box size handled by the 200a case sealer and decreases the minimum machine bed height.
Note – This also increases the minimum box height from 120 mm [4.75 inch] to 165 mm [6.5 inch].
To move the outer columns up one set of mounting holes:
1.Place minimum 305 mm [12 inch] high blocks at the front and rear of the upper taping head assembly as shown in Figure
2.Remove and retain the six screws and plain washers that fasten each column to the frame. Figure
3.Turn the height adjustment crank clockwise to raise the outer columns up one set of mounting holes (100 mm [4 inch]).
WARNING – Blocks and spacers must be capable of supporting the 34 Kg [75 pound] weight of the outer columns and upper taping head assembly.
4.Install and tighten the six screws and plain washers in each column that were removed in Step 2. Crank upper taping head assembly up and remove blocks.
If desired, the bed height can now be decreased to 520 mm [20.5 inch] by adjusting legs upward. (See "Installation and
24