6.0Install Termination

6.1Slide the termination body onto the cable and remove core. Make sure the termination body (not the core) is butted

up to the edge of the vinyl tape marker previously applied (Figure 7). Pull the core while unwinding, counter- clockwise, starting with the loose end (Figure 7). Be sure to alternate the pulling and unwinding actions (pull- unwind-pull-unwind-etc.) to help prevent the core material from binding up as the core is being removed.

NOTE: Once the termination body makes contact over the mastic seal area, there is no need to continue supporting the assembly. Do not push or pull on the termination assembly while unwinding the core.

Counterclockwise

Vinyl Tape Marker

NOTE: The material being removed at this step is mixed polymers

 

and can be recycled.

Figure 7

6.2Connect ground braid to system ground according to standard practice.

Correct Installation of Termination on Tape Shielded Cable

 

Vinyl Tape

 

 

Marker

Ridge at End of Cable

 

 

 

 

Insulation Shield (Semi-Con)

 

Ridge at End

 

 

of High-K Tube

 

 

Semi-Con Insulation Shield

Cable Insulation

Environmental Top

Stress Controlling Compound

Conductor

Seal

 

 

 

High-K Stress

 

 

Relief Tube

6

78-8113-5099-6 Rev E

Page 6
Image 6