12 |
|
| EX II 3000SP Controller Reference Guide | ||
| Table 1 COM Cable for EX II 3000SP Controller | ||||
|
|
|
|
|
|
| PC Side | Wire | Controller Side |
| |
| Pin | Color | Pin | Description |
|
| 1 |
| NC |
|
|
| 2 | White | 4 | Receive data (RXD) |
|
| 3 | Red | 3 | Transmit date (TXD) |
|
| 4 |
| NC |
|
|
| 5 | Black | 2 | Ground (also connects to grey wire) |
|
| 6 |
| NC |
|
|
| 7 |
| NC |
|
|
| 8 |
| NC |
|
|
| 9 |
| NC |
|
|
| Shell |
| NC |
|
|
| NC |
| 1 | +12V to orange wire |
|
Mounting the Controller
The controller should be mounted on the chassis inside the monitor.
Supplying Power to the Controller
You must supply the EX II 3000SP controller with power internally (+12 VDC) through a custom serial cable configuration. Exact specifications can be found in Appendix A.
Note: However you supply power, the source must deliver >100 mA @ 12V ±5% typical with a maximum ripple and noise of 50mV
Using a Custom Serial Cable Design
When creating a custom serial cable connection, you can provide power to the controller through the mating Molex connector:
1.Obtain a
2.Attach power and return to the connector (Pin 1: +12V, Pin 2: Ground).
3M Touch Systems Proprietary Information