22

 

EX II 3000SP Controller Reference Guide

 

Table 3 Firmware Commands for EX II 3000SP Development

 

 

 

 

 

Command NameCode

Description

 

 

Pen or Finger

PF

The controller recognizes both TouchPen and finger touch. This is

 

 

 

 

the default setting.

 

 

Calibrate Extended

CX

Initiates an interactive, two-point calibration.

 

 

Calibrate Raw

CR

Collects the raw X and Y coordinates prior to normal scaling,

 

 

 

linearization, and filtering process.

 

 

Finger Only

FO

The controller disables the TouchPen and only recognizes finger

 

 

 

touch on the screen.

 

 

Format Raw

FR

Returns the signal level (amount of touch) of each of the four touch

 

 

 

screen corners in digital format.

 

 

Format Tablet

FT

Outputs the X/Y touch coordinate data in a five-byte packet.

 

 

 

Preferred for current development.

 

 

Mode Stream

MS

Sends a continuous stream of X/Y coordinate data when you touch

 

 

 

the screen.

 

 

Null Command

Z

Queries the controller and waits for a response.

 

 

Output Identity

OI

Identifies the controller type and the firmware version.

 

 

Pen Only

PO

The controller is set to only recognize input from the TouchPen and

 

 

 

ignores any finger contact on the touch screen.

 

 

Reset

R

Initializes the hardware and the firmware, causes the controller to

 

 

 

stop sending data, and recalculates the environmental conditions.

 

 

 

Note: 2-pt calibration data is lost.

 

 

Restore Defaults

RD

Returns the controller to the factory default operating parameters.

 

 

 

Note: the serial port is reset to N81 data format and 2-pt calibration

 

 

 

data is lost.

 

 

Unit Type

UT

Identifies the touch screen controller on your system.

 

 

 

 

 

3M Touch Systems Proprietary Information