30

EX II 3000SP Controller Reference Guide

Output Identity

Syntax: <SOH>OI<CR>

Description: Returns a 6-character identifier, which describes the controller type and the firmware version number.

Response: <SOH>CcXxxx<CR>

where:

 

 

Cc

=

Two ASCII characters that describe the type of 3M Touch

 

 

Systems controller.

 

 

P5 = EX II 3000SP

Xxxx

=

Four ASCII characters that indicate the firmware version number

 

 

in decimal format. The first two characters represent the version

 

 

number; the last two characters represent the revision level. For

 

 

example, 0800 means Version 8, Revision 0 (that is, 8.0).

Pen/Finger

Syntax: <SOH>PF<CR>

Description: The default setting for the EX II 3000SP controller. It will recognize touch from either the TouchPen or finger.

Response: <SOH>0<CR> Positive response

Pen Only

Syntax: <SOH>PO<CR>

Description: The controller will disable finger touch and will only respond to the TouchPen.

Response: <SOH>0<CR> Positive response

Reset

Syntax: <SOH>R<CR>

Description: Initializes the hardware and the firmware, causes the controller to stop sending data, and recalculates the environmental conditions (for example, stray and offset values). The Reset command also cancels the Format Raw and Calibrate Raw commands and returns the controller to normal operation.

3M Touch Systems recommends that the host system issue a Reset command whenever the host system is powered on and is attempting to establish communication with the controller.

3M Touch Systems Proprietary Information