EX II 3000SP Controller Communications | 29 | |||
| Table 9 Format Tablet Status Bits | |||
|
|
|
| |
| Bit | Description | Values |
|
| S0 – S5 | Reserved | — |
|
| S6 | Proximity | 1 = Touch screen is being touched (a touchdown | |
|
| (touch state) | or a continued touch). | |
|
|
| 0 = Touch screen is not being touched (a touch | |
|
|
| liftoff or inactive). | |
|
|
| When the proximity bit changes from 1 to 0 | |
|
|
| (touch liftoff), the controller outputs one final set | |
|
|
| of X/Y coordinate data with the bit equal to 0 and | |
|
|
| the X/Y coordinate data equal to the last touch | |
|
|
| point. | |
| S7 | Packet | Always 1. | |
|
| synchronization |
|
|
Mode Stream
Syntax: <SOH>MS<CR>
Description: Sends a continuous stream of X/Y coordinate data when you touch the screen. The controller continues to send data as long as you touch the screen. The controller sends the data even if the touch is stationary and unchanging.
The format of the coordinate data depends on the last format command received by the controller.
Format Raw automatically uses Mode Stream to send X/Y coordinate data. Response: <SOH>0<CR> Positive response
Null Command
Syntax: | <SOH>Z<CR> |
Description: | Queries the controller and waits for a response. |
| Use Z to determine that you are communicating with the controller or to |
| make sure that a utility is communicating with the controller. Using this |
| command does not affect the controller’s current operating parameters. |
Response: | <SOH>0<CR> Positive response |
3M Touch Systems Proprietary Information