14 | EX II 3000SP Controller Reference Guide |
When you
A flashing (or blinking) LED during
Table 2 LED Diagnostic Codes for EX II 3000SP Controllers
LED | Error Description | What to do... |
Flashes |
|
|
1 | Reserved |
|
2 | Reserved |
|
3 | Setup error. Unable to establish operating | Replace controller. If error reoccurs, |
| range at | might be a touch screen problem. |
4Controller NOVRAM error. The operating parameters in the controller NOVRAM are invalid. Using defaults.
Restore defaults (RD command). If fault persists, replace controller. If error reoccurs, might be a touch screen or cable problem.
5 | HDW error. The controller hardware | Replace controller. |
| failed (unable to initialize or load |
|
| program). |
|
6 | Reserved |
|
7 | Reserved |
|
8 | Reserved |
|
9 | Reserved |
|
10 | Controller EEPROM not formatted | Contact Tech Support or replace |
|
| controller. |
11 | Invalid controller block 5 | Not applicable to serial controller. |
12 | Invalid controller block 6 | Replace controller. |
What's Next?
Installing and Using TouchWare
TouchWare includes the software driver that lets your touch screen work with your computer. 3M Touch Systems has touch screen drivers for many operating systems, including Windows XP, 2000, 9x, Windows Me, Windows 3.1x, and Windows NT. Be sure to install the correct touch screen software for your operating system.