3M™ Digital Projector X30N/X35N
Maintenance
Cleaning and replacing the air filter
The air filter unit of this projector consists of a filter cover, two kinds of filters, and a filter frame. The new double large filters system is expected to function longer. However, please check and clean it periodically to keep ventilation needed for normal operation of the projector.
When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. Replace the filters when they are damaged or too soiled. Contact your dealer with the following part number.
Type number : 78-8138-1041-9 (MU06481(Filter set))
When you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector.If the filter needs to be cleaned prior to replacing the lamp and filter, it may be cleaned by using the following procedure
1. Turn the projector off, and unplug the power cord. Allow the projector to sufficiently cool down.
2. Use a vacuum cleaner on and around the filter cover.
3. While supporting the projector with one hand, use your other hand to pull the filter cover forward in the direction of the arrow.
4. Use a vacuum cleaner for the filter vent of the projector and the outer side of the filter unit.
5. Take the filters out while holding the filter cover.
6. Use a vacuum cleaner on both sides of the filters. When vacuuming up the fine meshed filter, hold it so it will not be sucked in. If the filters are damaged or heavily soiled, replace them with the new ones.
7. Put the filters back into the filter cover.
4
Filter cover | 2 |
|
3
Filter unit
Filter cover
Put the coarse meshed filter into a filter cover first. Then put the fine meshed filter on the coarse meshed one, turning its stitched side up.
8. Put the filter unit back into the projector.
7
Filter (coarse meshed) Filter (fine meshed)
Stitched side
(continued on next page)
64 | © 3M 2009. All Rights Reserved. |