A.O. Smith BFC - 80, BFC -100 service manual Preparation

Models: BFC - 80 BFC -100

1 96
Download 96 pages 7.52 Kb
Page 33
Image 33

is

Legend

A.screws

B.protective cap

C.connector block

Optionally, it is possible to connect an isolating transformer, a continuous pump, a program-controlled pump, an extra ON mode switch and an extra alarm signal to the appliance. For these options, see:

Isolating transformer;

Connecting a program-controlled pump;

Connecting an extra ON mode switch ("Tank ON");

Connecting an extra error signal ('Alarm OUT' ).

Note

The optional components are not included in the rating for electrical power consumption stated in the table (3.4.2 "General and electrical specifications").

3.10.2Preparation

Caution

The appliance is phase-sensitive. It is absolutely essential to connect the mains phase (L) to the phase of the appliance, and the mains neutral (N) to the neutral of the appliance.

Caution

There may be no potential difference between neutral (N) and earth (). If this is the case, then an isolating transformer must be applied in the supply circuit (3.10.4 "Isolating transformer").

For more information or to order this isolating transformer, please contact A.O. Smith water Products Company.

The figure shows a view of the electrical connector block, and the table shows the appropriate connections.

Connector block

A

B

A

24

C

1

IMD-0224 R3

Instruction manual BFC

33

Page 33
Image 33
A.O. Smith BFC - 80, BFC -100 service manual Preparation