The appliance's default week program switches the appliance on every day at 00:00 and off at 23:59. The default water temperature setting is 65°C.

If you want, you can change every setting in the appliance's standard week program.

If the water temperature becomes too low while the week program is running, the appliance will run through the heating cycle (9.3 "The appliance's heating cycle") and return to the week program.

This following are discussed:

Starting and stopping the week program

Changing the appliance's standard week program

Adding times to a week program

Deleting times from a week program

11.5Starting and stopping the week program

The week program can be started up from any other operating mode, as follows:

1. : WEEK PROGRAM START OPERATION

Confirm with .

A week program can be shut down simply by activating a different operating mode, for example the "ON mode".

11.6Changing the appliance's standard week program

Note

First fill-in the desired week program on the supplied week program card.

A week program is made up of a number of programmable periods in which you can have the appliance switch on and off. A period consists of:

switch-on time: day of the week, hours and minutes:

switch-off time: hours and minutes;

the water temperature setting;

on/off setting for a program-controlled pump.

Note

The switch-off time must always be followed by a switch-off time on the same day of the week. A maximum of three periods may be programmed per day. You can program a maximum of 21 periods.

Call up the menu for the week program as follows:

: WEEK PROGRAM PROGRAM OVERVIEW.

Confirm with .

WEEK PROGRAM START OPERATION

^»PROGRAM OVERVIEW

È

The display shows the menu for the week program, see the figure below. With the default setting, the program switches on and off every day at 00:00 and 23:59 hours respectively, the water temperature is 65°C and the pump is switched on (P).

 

DAY

TIME

Tset

ON »SU

00:00

65ÉC P

OFF

SU

23:59

 

ON

MO

00:00

65ÉC P

 

 

 

 

OFF

MO

23:59

 

ON

TU

00:00

65ÉC P

OFF

TU

23:59

 

ON

WE

00:00

65ÉC P

OFF

WE

23:59

 

ON

TH

00:00

65ÉC P

OFF

TH

23:59

 

ON

FR

00:00

65ÉC P

OFF

FR

23:59

 

ON

SA

00:00

65ÉC P

OFF

SA

23:59

 

INSERT

DELETE

START OPERATION

Example

As an example, we will set the switch-on time for Sunday to 08:15 hours, and the matching switch-off time to 12:45 hours. The water temperature will be set to 75 °C and the pump will run continuously.

The following settings are entered one by one via the menu: the switch-on time, the switch-off time, the desired water temperature, and the mode of the program-controlled pump.

11.6.1Week program: setting the switch- on time

1.Bring the cursor to SU

Confirm with .

ON

»SU 00:00

OFF

SU

23:59

Tset

65ÉC

PUMP

ON

SAVE

 

 

 

The day indicated by » flashes.

2.Use and to set the desired day. In the example this is SU (Sunday).

Confirm with .

ON

SU»00:00

OFF

SU

00:59

Tset

65ÉC

PUMP

ON

SAVE

 

 

 

The cursor moves to the hour digits, which flash.

3.Use and to set the hours. In the example, this is 08.

58

Instruction manual BFC

Page 58
Image 58
A.O. Smith BFC -100 Starting and stopping the week program, Changing the appliances standard week program, Main menu

BFC - 80, BFC -100 specifications

A.O. Smith is a renowned name in the water heater industry, and its BFC series, which includes the BFC-100 and BFC-80 models, exemplifies their commitment to innovation and efficiency. These units are designed to meet the demanding needs of both residential and commercial applications, providing reliable hot water solutions.

The A.O. Smith BFC-100 and BFC-80 are distinguished by their high capacity and robust design. The BFC-100 model boasts a capacity of 100 gallons, while the BFC-80 is ideal for those requiring 80 gallons. This makes them suitable for larger households or commercial establishments where hot water demand can be significant.

One of the primary features of these models is their advanced heating technology. Both units utilize a high-efficiency burner that ensures rapid heating and minimal energy consumption. This means users benefit from shorter wait times for hot water, reducing overall energy costs. The BFC series is also equipped with a special flame retention head that enhances combustion efficiency and prolongs the lifespan of the unit.

In terms of construction, the BFC-100 and BFC-80 models are built with high-quality materials that enhance durability and resistance to corrosion. The tanks are insulated with high-density foam, which improves energy retention and helps maintain water temperature for longer periods. This is crucial for conserving energy and minimizing heating costs.

Safety is a top priority for A.O. Smith, and the BFC series reflects this commitment. Each unit comes with a range of safety features, including a temperature and pressure relief valve that prevents overheating and excessive pressure buildup. Additionally, they are designed to meet strict industry standards, ensuring peace of mind for users.

Installation of both models is straightforward, with flexible venting options that accommodate various building layouts. Whether you are upgrading an existing water heating system or installing a new one, the BFC series is designed to integrate seamlessly.

In summary, the A.O. Smith BFC-100 and BFC-80 are excellent options for those seeking reliable, efficient, and durable water heating solutions. With their impressive capacity, advanced heating technology, robust construction, and safety features, these models stand out in the market and are sure to meet the hot water needs of any household or commercial space. Whether for residential use or in a business setting, A.O. Smith’s BFC series represents quality and innovation in hot water heating.