A.O. Smith BFC -100, BFC - 80 Code + Description Cause Solution Remark E01 blocking error

Models: BFC - 80 BFC -100

1 96
Download 96 pages 7.52 Kb
Page 80
Image 80

is

Code + Description

Cause

Solution

Remark

 

 

 

 

E01 (blocking error)

The temperature of the

None. This is a temporary message that may appear from time to

 

 

water at the top of the

time, but will disappear automatically.

 

The temperature

tank is > 85 oC.

 

 

 

protection at the top of

 

 

 

 

the tank has been

 

 

 

 

activated.

 

 

 

 

E03 (lock-out error)

The two temperature

1.

Check sensor position and wiring.

To replace the necessary parts, you must contact your installation

 

sensors in the tank

2.

If necessary, reset the electronic controller. Replace the sensor

engineer

Error in temperature

detect a differential of >

 

sensor T at the top of

10 oC over a period of

 

if the error persists.

 

the tank.1

at least 60 seconds.

 

 

 

E04 (lock-out error)

The two dummy

1.

Check leads from dummy 1 and dummy 2.

To replace the necessary parts, you must contact your installation

 

sensors in the tank

2.

If necessary, reset the electronic controller. Replace the dummy

engineer

Error in dummy

detect a differential of >

 

sensor(2).

10 oC over a period of

 

sensor if the error persists.

 

 

at least 60 seconds.

 

 

 

1)Temperature sensor T1 is a '2 in 1' sensor, T1 contains 2 NTCs for the high-limit thermostat and safety thermostat protection.

(2) The dummy sensor / flue gas sensor comprises dummy sensor / flue gas sensor 1 and dummy sensor / flue gas sensor 2.

Instruction manual BFC

80

Page 80
Image 80
A.O. Smith BFC -100 Code + Description Cause Solution Remark E01 blocking error, E03 lock-out error, E04 lock-out error