A.O. Smith BFC - 80 Week program setting the switch- off time, Adding times to a week program

Models: BFC - 80 BFC -100

1 96
Download 96 pages 7.52 Kb
Page 59
Image 59

gis

Confirm with .

The cursor moves to the minute digits, which flash.

ON

SU 08»00

 

OFF

SU

08:00

 

Tset

65ÉC

 

PUMP

ON

SAVE

 

 

 

 

 

Note

Because the switch-off time can never be earlier than the switch-on time, the switch-off time setting is automatically adjusted with the switch-on time.

4.Use and to set the minutes. In the example, this is 15.

Confirm with .

The cursor moves to the switch-off hour digits, which flash.

ON

SU

08:15

OFF

SU»08:15

Tset

65ÉC

PUMP

ON

SAVE

 

 

 

11.6.2Week program: setting the switch- off time

1.Use and to set the hours. In the example, this is 12.

Confirm with .

The cursor moves to the minute digits, which flash.

ON

SU 08:15

OFF

SU

12»15

Tset

65ÉC

PUMP

ON

SAVE

 

 

 

2.Use and to set the minutes. In the example, this is 45.

Confirm with .

The cursor moves to the desired water temperature.

ON

SU 08:15

OFF

SU

12:45

Tset»65ÉC

PUMP ON

SAVE

 

 

 

11.6.3Week program: setting the water temperature

1.Use and to set the water temperature. In the example this is 75°C.

Confirm with .

The cursor moves to PUMP ON

ON SU 08:15

OFF SU 12:45

Tset 75ÉC

PUMP»ON SAVE

11.6.4Week program: setting the program- controlled pump

1.If required, a pump can be controlled during the period. Use and to set PUMP ON . The pump ensures a regular circulation of hot water in the hot water pipes. You can skip this step if you there is no pump in your hot water circuit.

Confirm with

.

The cursor moves to

SAVE.

ON SU 08:15

OFF SU 12:45

Tset 75ÉC

PUMP»ON SAVE

2.Confirm with .

The display shown in the figure will appear.

 

DAY

TIME Tset

ON »SU

08:15 75ÉC P

OFF SU

12:45

ON

MO

00:00 65ÉC P

 

 

 

OFF

MO

23:59

ON

TU

00:00 65ÉC P

OFF

TU

23:59

 

 

 

3.If you wish, you can use to scroll to another day, and change more switch-on times (11.6.1 "Week program: setting the switch-on time") and switch- off times (11.6.2 "Week program: setting the switch-off time").

4.After changing all desired switch-on and switch off times, you can start running the week program:

Scroll with to START OPERATION.

Confirm with .

11.7 Adding times to a week program

Call up the menu to INSERT switch-on and switch-off times into a week program as follows:

1.: WEEK PROGRAM PROGRAM OVERVIEW.

Confirm with .

WEEK PROGRAM START OPERATION

^»PROGRAM OVERVIEW

È

Instruction manual BFC

59

Page 59
Image 59
A.O. Smith BFC - 80, BFC -100 Week program setting the switch- off time, Week program setting the water temperature

BFC - 80, BFC -100 specifications

A.O. Smith is a renowned name in the water heater industry, and its BFC series, which includes the BFC-100 and BFC-80 models, exemplifies their commitment to innovation and efficiency. These units are designed to meet the demanding needs of both residential and commercial applications, providing reliable hot water solutions.

The A.O. Smith BFC-100 and BFC-80 are distinguished by their high capacity and robust design. The BFC-100 model boasts a capacity of 100 gallons, while the BFC-80 is ideal for those requiring 80 gallons. This makes them suitable for larger households or commercial establishments where hot water demand can be significant.

One of the primary features of these models is their advanced heating technology. Both units utilize a high-efficiency burner that ensures rapid heating and minimal energy consumption. This means users benefit from shorter wait times for hot water, reducing overall energy costs. The BFC series is also equipped with a special flame retention head that enhances combustion efficiency and prolongs the lifespan of the unit.

In terms of construction, the BFC-100 and BFC-80 models are built with high-quality materials that enhance durability and resistance to corrosion. The tanks are insulated with high-density foam, which improves energy retention and helps maintain water temperature for longer periods. This is crucial for conserving energy and minimizing heating costs.

Safety is a top priority for A.O. Smith, and the BFC series reflects this commitment. Each unit comes with a range of safety features, including a temperature and pressure relief valve that prevents overheating and excessive pressure buildup. Additionally, they are designed to meet strict industry standards, ensuring peace of mind for users.

Installation of both models is straightforward, with flexible venting options that accommodate various building layouts. Whether you are upgrading an existing water heating system or installing a new one, the BFC series is designed to integrate seamlessly.

In summary, the A.O. Smith BFC-100 and BFC-80 are excellent options for those seeking reliable, efficient, and durable water heating solutions. With their impressive capacity, advanced heating technology, robust construction, and safety features, these models stand out in the market and are sure to meet the hot water needs of any household or commercial space. Whether for residential use or in a business setting, A.O. Smith’s BFC series represents quality and innovation in hot water heating.