A.O. Smith FPS 75 SERVICE AND OPERATION cant, then, the meter does not read 24 VAG, Results

Models: FPS 75 FPSE50 FPS40 fps50

1 103
Download 103 pages 20.94 Kb
Page 91
Image 91
replace the I.I.D.

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK

FPS 75 SERVICE AND OPERATION cant.

Trouble- BLOWER RUNS CONSTANTLY (Calling for heat, pilot is lit, no main burner) shootingcont. cant.

RESULTS

 

If:

then:

the meter does not read 24 VAG,

replace the I.I.D.

the meter does read 24 VAG,

go to Step 2.

Page 91
Image 91
A.O. Smith FPSE50 FPS 75 SERVICE AND OPERATION cant, then, the meter does not read 24 VAG, replace the I.I.D, Results