A.O. Smith FPS40, FPSE50, fps50, FPS 75 manual Service Checklist, Comments

Models: FPS 75 FPSE50 FPS40 fps50

1 103
Download 103 pages 20.94 Kb
Page 98
Image 98
SERVICE CHECKLIST

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK

SERVICE CHECKLIST

VI

PROPER SEQUENCE OF OPERATION

A. FPS40 - 50

During standby is blower off?

On a call for heat does gas valve open? Does gas pressure switch close?

Does the blower come on?

If so, does the air pressure make? Does the solenoid open?

Does main burner ignite? Does the thermostat satisfy?

Comments:

A.FPSE40-50

During standby is blower off?

On a call for heat does gas valve open? Does gas pressure switch close?

Does the blower come on?

If so, does the air pressure make? Does the solenoid open?

Does main burner ignite? Does the thermostat satisfy?

Comments:

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

yes no

A. FPD40 - 50

 

 

During standby is blower off?

yes

no

On a call for heat does gas valve open?

yes

no

Does gas pressure switch close?

yes

no

Does the blower come on?

yes

no

If so, does the air pressure make?

yes

no

Does the solenoid open?

yes

no

Does main burner ignite?

yes

no

Does the thermostat satisfy?

yes

no

Comments:

 

 

A. FPS75

 

 

During standby is blower off?

yes

no

On a call for heat does gas valve open?

yes

no

Does gas pressure switch close?

yes

no

Does the blower come on?

yes

no

If so, does the air pressure make?

yes

no

Does the solenoid open?

yes

no

Does main burner ignite?

yes

no

Does the thermostat satisfy?

yes

no

Comments

@1995

 

 

A.D. Smith

97

Technical Information

Water Products Co

Irving, Texas

Page 98
Image 98
A.O. Smith FPS40, FPSE50, fps50, FPS 75 manual Service Checklist, Comments