A.O. Smith FPSE50 FPS 40 and 50 SERVICE AND OPERATION cant, shooting cont, Technical Information

Models: FPS 75 FPSE50 FPS40 fps50

1 103
Download 103 pages 20.94 Kb
Page 36
Image 36
Manual background

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK

FPS 40 and 50 SERVICE AND OPERATION cant

Trouble-

BLOWER RUNS CONSTANTLY (No main burner) cont.

shooting cont.

RESULTS

 

If:

then

the meter does not read 120 VAG,

replace the air switch

the meter does read 120 VAG,

go to Step 2

@1995

A.D.Smith

35

Technical Information

Water Products Co

Irving, Texas

Page 36