A.O. Smith FPS40, FPSE50 Trouble- MAIN BURNER PROBLEMS, FPSE 40 and 50 SERVICE AND OPERATION cont

Models: FPS 75 FPSE50 FPS40 fps50

1 103
Download 103 pages 20.94 Kb
Page 66
Image 66
Trouble- MAIN BURNER PROBLEMS

FPS/FPSE/FPD TECHNICAL TRAINING AND SERVICE WORKBOOK

FPSE 40 and 50 SERVICE AND OPERATION cont.

FPD 40 and 50 SERVICE AND OPERATION cont.

Trouble- MAIN BURNER PROBLEMS

shooting cont.

The following are possible causes of main burner problems:

1.Unlevel burner will cause yellow flames.

2.Burning and the orifice indicates main gas valve may not be fully closing.

3.Incorrect gas pressure; it should be 3.5" for natural gas and 10" for propane.

4.Soot build-up. Check gas pressure and air flow through heater and venting.