![Surface Mounted Thermostat (s) and High Limit (s)](/images/new-backgrounds/206673/20667341x1.webp)
RESIDENTIAL GAS AND ELECTRIC WATER HEATER
SERVICE HANDBOOK
Residential Electric – continued
Surface Mounted Thermostat (s) and High Limit (s)
The thermostats and high limits are held against the side of the tank. As the tank surface heats or cools, a metal disc inside of the control expands or contracts to open or close electrical contacts in the controls.
They will satisfy within 10°F of setting. The tank surface has to cool 8 - 15°F to reactivate these controls.
|
|
| Newer |
| Temperature |
Model | Circuit | Older Models | Models1 | Location | Range °F |
X |
| Upper Tank | |||
X | X | Lower Tank | |||
|
|
|
|
| |
389T33 |
| X | Upper Tank | ||
389T13 |
| X | Lower Tank | ||
| X | Lower Tank | |||
X | X | Upper Tank | |||
|
|
|
|
|
|
X | X | Lower Tank | 190° | ||
|
|
|
|
| |
389T |
| X |
| 170° | |
|
|
|
|
|
1”Older” = series 916 or older.
“Newer” = series 917 or more current – (Began approximately January, 1996)
2Older 59T controls had a maximum setting of 170°F. Replacement 59T controls will stop at 150°F.
389T controls are combination High Limit/Thermostat, one piece controls.
466T limits may be mounted onto 59T thermostats.
66T4400
59T4100
Thermostat
59T4100
Combination High Limit &
Thermostat
89T 33
A.O. Smith Water Products Company | 20 | Training Department | |
©2002 | Ashland City, Tennessee | ||
|