Surface Mounted Thermostat (s) and High Limit (s)

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

Surface Mounted Thermostat (s) and High Limit (s)

The thermostats and high limits are held against the side of the tank. As the tank surface heats or cools, a metal disc inside of the control expands or contracts to open or close electrical contacts in the controls.

They will satisfy within 10°F of setting. The tank surface has to cool 8 - 15°F to reactivate these controls.

 

 

 

Newer

 

Temperature

Model

Circuit

Older Models
Models1

Location

Range °F

259T-Style 4100

A-6, A-7

X A-6

 

Upper Tank

110-170

259T-Style 4000

A-6, A-7,

X

X

Lower Tank

110-170

 

C-2

 

 

 

 

389T33

A-6

 

X

Upper Tank

90-150

389T13

C-2, A-7

 

X

Lower Tank

90-150

259T-Style 4000

A-6

 

X

Lower Tank

90-150

2AW-Style 7135

A-7

X

X

Upper Tank

110-170

 

 

 

 

 

 

466T-Style 4400

A-6, A-7,

X

X

Lower Tank

190°

 

C-2

 

 

 

 

389T

A-6, A-7,

 

X

 

170°

 

C-2

 

 

 

 

1Older” = series 916 or older.

“Newer” = series 917 or more current – (Began approximately January, 1996)

2Older 59T controls had a maximum setting of 170°F. Replacement 59T controls will stop at 150°F.

389T controls are combination High Limit/Thermostat, one piece controls.

466T limits may be mounted onto 59T thermostats.

66T4400

59T4100

Thermostat

59T4100

Combination High Limit &

Thermostat

89T 33

A.O. Smith Water Products Company

20

Training Department

©2002

Ashland City, Tennessee

 