Complaint:

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

C-2 – service continued

Complaint:

No Hot Water

Conditions:

Tank water cold

Power on

Procedure:

Multimeter set for

AC voltage check

 

 

Voltage Checks

 

 

 

Test voltage between 1 and 3 or L1 and L3 of high limit.

 

 

 

If …

 

… then

 

 

 

rated voltage is not present

 

check circuit breaker (fused disconnect)

 

 

 

 

check wire connections in heater junction

 

 

 

 

box

 

 

 

 

 

check position of heater ON/OFF switch-if

 

 

 

 

applicable.

 

 

 

rated voltage is present

 

continue to next step.

 

 

 

Test voltage between 2 and 4 or L1 and L4 of high limit

 

 

 

If …

 

… then

 

 

 

rated voltage is not present

 

press high limit reset button

 

 

 

 

replace high limit (after conducting

 

 

 

 

thermostat check)

 

 

 

 

 

 

 

 

 

rated voltage is present

 

continue to next step.

 

 

 

Test voltage between 4 and 2 or T2 and L4

 

 

 

If …

 

… then

 

 

 

rated voltage is not present

 

check jumper between high limit 2 and

 

 

 

 

thermostat 1or

 

 

 

 

 

on T2, L4 test-replace control.

 

 

rated voltage is present

 

continue to next step.

 

 

 

 

 

 

 

 

 