A.O. Smith TC-049-R2 Service Handbook, Residential Gas And Electric Water Heater, If …, … then

Models: TC-049-R2

1 61
Download 61 pages 40.26 Kb
Page 34
Image 34
Test between the two element terminals

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

C-2 service “No Hot Water” – continued

Test between the two element terminals

If …

… then

rated voltage is not present

check wiring from control.

rated voltage is present

repeat Ohms resistance test of element

 

check for water leaks in piping or fixtures.

Complaint: Water Too Hot

 

Conditions:

 

Tank water above thermostat setting +10°F

 

Power on

 

Voltage Check

Test between 4 and 2 or L4 and T2

If …

… then

rated voltage is present

replace thermostat control.

lower than rated voltage is present

test for grounded element.

no voltage is present

test complete.