A.O. Smith TC-049-R2 Service Handbook, Residential Gas And Electric Water Heater, Construction

Models: TC-049-R2

1 61
Download 61 pages 40.26 Kb
Page 5
Image 5
Centimeters = Inches X 2.54

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

General Section – continued

%Thermal Efficiency = (GPH X 8.25 X Temp. Rise X 1.0) divided by BTU/H Input

BTU Output = GPH X 8.25 X Temp. Rise X 1.0

GPH = (BTU/H Input X % Eff.) divided by (Temp. Rise X 8.25)

One cubic foot of Natural Gas contains about 1000 BTU of heat.

One “thermis equal to 100,000 BTU

One cubic foot of Propane Gas contains about 2500 BTU of heat.

One gallon of Propane gas contains about 91,250 BTU of heat.

One pound of Propane gas contains about 21,600 BTU of heat.

One pound of gas pressure is equal to 27.7 inches water column pressure Inches of Water Column X .036091 = PSI

Inches of Water Column X .073483 = Inches of Mercury (Hg.)

Centimeters = Inches X 2.54

MM(millimeters) =Inches X 25.4

Meters = Inches X .0254

Doubling the diameter of a pipe will increase its flow capacity (approximately) 5.3 times.

CONSTRUCTION:

Tank is constructed of steel.

The inside of the tank is constructed of a glass lining bonded to the steel. This prevents water to metal contact and rusting of the tank.

An anode rod will be installed within the tank. The hex-head plug end of the anode is visible on the top of the water heater. This metal rod offers secondary protection of the tank against corrosion where the application of glass is not possible (threaded tank openings). These areas will have small areas of water to metal contact.

All water heaters will contain at least one thermostat (to operate the heater) and one high limit (to prevent water temperatures approaching the “steam” level).

A.O. Smith Water Products Company

4

Training Department

©2002

Ashland City, Tennessee

 

Page 5
Image 5
A.O. Smith TC-049-R2 manual Service Handbook, Residential Gas And Electric Water Heater, Construction