Test Condition

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

A-7 service – Voltage Checks “Lack of Hot Water” – continued

Test Condition

Lower tank water is at least 15°F below lower thermostat setting

Test between lower high limit 4 and lower thermostat 2 or lower high limit L4 and lower thermostat T2

If …

… then

proper voltage is not present:

check jumper between lower high limit

 

 

2 and lower thermostat 1.

 

replace lower thermostat.

proper voltage is present:

continue to next step.

Test between the terminals of the lower element

If …

… then

proper voltage is not present:

check wire connections to lower controls.

proper voltage is present:

conduct grounded element checks.

A.O. Smith Water Products Company

43

Training Department

©2002