A.O. Smith TC-049-R2 manual Service Handbook, Residential Gas And Electric Water Heater

Models: TC-049-R2

1 61
Download 61 pages 40.26 Kb
Page 40
Image 40
Testing The A-7 Wiring Circuit

RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

Testing The A-7 Wiring Circuit

A-7 Circuit:

Two elements

Two thermostats

Two high limits

Four wires

Non-simultaneous operation or simultaneous

Prior To 1996

Post 1995

Supply wiring may be a: (See Pages 25 and 27)

1.three wire, 3 phase circuit:

2.two wire, single phase circuit or

3.connection to an off peak meter or time clock.

This third, wiring system interrupts power to the lower thermostat during the designated time period but does not interrupt power to the upper thermostat.

If the consumer uses enough of the stored hot water to drop tank temperature at the top of the tank to call for upper element activation, then the upper element will reheat the upper third of the tank

A.O. Smith Water Products Company

39

Training Department

©2002

Ashland City, Tennessee

 

Page 40
Image 40
A.O. Smith TC-049-R2 Service Handbook, Residential Gas And Electric Water Heater, Supply wiring may be a See Pages 25 and