RESIDENTIAL GAS AND ELECTRIC WATER HEATER

SERVICE HANDBOOK

Residential Electric – continued

A-7 Service – continued

Element Test

OHMS Resistance Check**

Test Conditions:

Element(s) not heating or water becoming excessively hot. This test uses the multimeter's battery as the electrical supply.

Procedure:

Power to the water heater is "OFF".

Multimeter set to OHMS scale testing.

Black lead "Common" port.

Red lead in "Ω" or " OHMS" port.

Dial indicator set to scale above expected indication.

Note: Volts divided by amps = OHMS

Element

Disconnect wires from the element terminals.

See OHMS Resistance Table – Page 45

Test probe on each terminal of an element

If …

… then

proper resistance (+7.5%) is present

continue testing.

meter reads “0”

check OHM scale setting

 

replace element.

 

 

meter reads “1” or off scale

replace element.

 

 

 

** The above test can also be conducted with the element removed from the tank.

A.O. Smith Water Products Company

40

Training Department

©2002

Ashland City, Tennessee

 