OPERATING INSTRUCTIONS
Fig 5d
Fig 5e
Step 3. To turn the main burner off while keeping the pilot alight, rotate the operating knob back to the PILOT position. (Fig 5e)
Fig 5f
Step 4. To extinguish the pilot, turn the control knob to the OFF position. (Fig 5f)
Incorporated into the pilot assembly is a flame failure device designed to shut off the gas supply in the event of the pilot flame being extinguished while the fire is unattended.
Should the pilot flame blow out accidentally or intentionally whilst the fire is running, no attempt should be made to
To restart the fire turn the control knob to the off position and repeat the lighting & controlling the fire instructions.
The flame failure device is a safety feature required by law and must not be put out of action by the installer. If this device or any of its parts are to be replaced, only original manufacturer's parts are to be used.
Repeated operation of the flame failure device indicates that there maybe a problem with the flue draw. In this situation no more attempts at operating the appliance should take place and your qualified gas engineer should be contacted to investigate and rectify the problem.
10 | Becton Bunny & Becton 7 mk3 Gas stoves |