OPERATING INSTRUCTIONS

LIGHTING & CONTROLLING THE FIRE

Under no circumstance must the fire be operated if the glass is cracked or broken.

Open the gas control access door situated at the bottom of the appliance. Always use the control door HANDLE.

Step 1a. To ignite the pilot push the control knob in, turn anti-clockwise towards the spark position and hold in for 15 seconds. (Fig 5a)

The pilot can be viewed through the L/H & centre front slots in the base matrix.

Fig 5a

Step 1b. Keep the control knob pressed in and turn

anti-clockwise to the pilot position. (Fig 5b)

Fig 5b

Step 1c. Keep the control knob pressed in for a further 15 seconds and then release. The pilot will remain alight.

If pilot does not remain alight repeat this procedure.

Please note that when purging the gas supply it is usual to have to keep the control knob depressed in the spark position for longer periods of time.

Step 2. To ignite the main burner, rotate the control knob anti-clockwise to the HIGH position (fig 5c)

Fig 5c

For maximum heat output leave the control knob at the high position

For minimum heat output, rotate the control knob clockwise to the LOW position. (Fig 5d)

Becton Bunny & Becton 7 mk3 Gas stoves

9

Page 9
Image 9
Aarrow Fires Becton 7 mk3, Becton Bunny installation manual Operating Instructions Lighting & Controlling the Fire