Aarrow Fires Becton 7 mk3 Servicing Annual Service, Cleaning Outer Surfaces, Cleaning the Glass

Models: Becton Bunny Becton 7 mk3

1 32
Download 32 pages 61.57 Kb
Page 21
Image 21

SERVICING

ANNUAL SERVICE

THIS GAS APPLIANCE MUST BE SERVICED EVERY TWELVE MONTHS BY A QUALIFIED GAS ENGINEER.

See "SAFETY NOTICES" ref coal set page 4.

Ensure the appliance is cold.

Step 1 Isolate the gas supply to the fire using the gas cock supplied at installation.

Step 2 Open the fire door, (Held closed using a magnet).

Step 3 Remove the glass frame and the glass/ gasket assembly.

Step 4 Carefully remove and clean the coal set of any soot deposits using a soft brush.

Step 5 Carefully remove and clean the firebox linings. Where necessary.

Step 6 Inspect the chimney and flue terminal ensuring they are in good working order and sweep as necessary to ensure no debris blocks the flue. Please note periodic chimney sweeping is vital to gas fire maintenance.

Step 7 Remove matrix location plate and valve heat shield. Clean any soot deposits from inside the fire using a vacuum cleaner. See “Safety notes”on page 4.

Step 13 Replace glass/gasket and glass frame and close the fire door.

Step 14 Carry out spillage test as per instructions on page 16.

CLEANING OUTER SURFACES

To clean the outside first the appliance must be cold.

The outside finish of the fire is a durable high temperature paint, this will give off a slight odour during the first few days of operation. It is best cleaned by using a soft brush. Do not allow moisture to remain on the fire whilst cold or surface rust may occur.

CLEANING THE GLASS

To clean the glass the appliance must be cold.

Step 1 Open the fire door. (This is held closed using a magnet)

Step 2 Remove the glass frame and the glass/gasket assembly (See page 19).

Take care not to damage the glass or gasket when cleaning.

Step 3 Replace glass frame and the glass/gasket assembly. Close the fire door.

Step 8 Inspect the pilot assembly to ensure that it is clean, unobstructed and in good order.

Step 9 Check system for gas soundness.

Step 10 Replace heat shield and matrix location plate.

Step 11 Replace fire box linings.

Step 12 Replace coal set.