SERVICING

START

FAULT DIAGNOSIS

Does the pilot ignite?

No

Is the gas supply turned on?

Yes

Is the supply pressure correct?

Yes

Is their a spark at the electrode?

Yes

Check to ensure the pilot assy is not obstructed or faulty

Yes

No

Turn gas on

No

Correct pressure

No

Check piezo igniter

Does the pilot stay alight?

No

Is their air in the system?

No

Is the thermocouple o.k.?

Yes

Is pilot injector obstructed?

No

Has spillage monitoring system been activated?

Yes

Yes

Purge system

No

Correct

alignment or

replace

Yes

Clean

No

Does the main burner light?

No

Is the main injector blocked?

No

Is the flue blocked?

No

Confirm supply pressure is correct

Yes

Fire satisfactory

Yes

Clean and replace as necessary

Carry out smoke test

Yes

Investigate flue systems

Check all pipe connections check main valve magnet

22

Becton Bunny & Becton 7 mk3 Gas stoves

Page 22
Image 22
Aarrow Fires Becton Bunny, Becton 7 mk3 installation manual Servicing, Fault Diagnosis