INSTALLATION

non- combustible closure plate, incorporating access for cleaning debris.

Fig. 7b.

Fig. 7c

non- combustible closure plate, incorporating access for cleaning debris.

Fig. 7d.

FIRE LOCATION

The appliance must not be installed in a room or space, which contains a bath or shower.

This fire is designed for use with either top or rear flue outlets and must be mounted on a hearth with a minimum of 12mm non-combustible material thickness.

There must be a minimum of 200mm clearance from the sides of the fire to any combustible sidewalls. Fig7a.

For clearance from the top of the fire to any combustible shelf. Fig 7b. (See Graph 1).

There must be a minimum of 230mm from the rear of the fire to any combustible back wall. Fig 7b.

With a Non-combustibleback wall the fire can be pushed back until the top diverter touches the wall, although to improve access and air circulation a minimum distance of 100 mm is recommended.

Fig 7c.

Reference non-combustible side walls a minimum of 100mm is recommended.

Do not place any furniture or furnishings (including curtains) within 1 metre of the fire.

Becton Bunny & Becton 7 mk3 Gas stoves

13

Page 13
Image 13
Aarrow Fires Becton 7 mk3, Becton Bunny installation manual Fire Location