-Beep Temp.

This item selects the warning temperature limit.

The shutdown temperature must be set above the warning temperature.

Voltage Monitoring

Click <Enter> key to enter its submenu:

µGuru Utility v1.00C

ABIT EQ

Voltage Monitoring

 

Reading

Shutdown

Beep

High

 

Low

 

 

 

Enable

Enable

Limit

 

Limit

 

(*)CPU Core Voltage

1.27

V (*)

(*)

1.55

V

0.00

V

(*)DDR Voltage

1.80

V ( )

(*)

2.15

V

1.45

V

(*)DDR VTT Voltage

0.89

V ( )

(*)

1.05

V

0.70

V

(*)CPU VTT 1.2V Voltage

1.20

V ( )

(*)

1.45

V

0.95

V

(*)MCH & PCIe 1.5V Voltage

1.50

V ( )

(*)

1.80

V

1.20

V

(*)MCH 2.5V Voltage

2.50

V ( )

(*)

3.00

V

2.00

V

(*)ICH 1.05V Voltage

1.05

V ( )

(*)

1.25

V

0.85

V

(*)ATX +12V (24-Pin Connector)

12.00

V ( )

(*)

14.40

V

9.60

V

(*)ATX +12V (4-Pin Connector)

12.00

V ( )

(*)

14.40

V

9.60

V

(*)ATX +5V

5.00

V ( )

(*)

6.00

V

4.00

V

(*)ATX +3.3V

3.30

V ( )

(*)

3.95

V

2.65

V

(*)ATX 5VSB

5.00

V ( )

(*)

6.00

V

4.00

V

 

 

 

￿￿￿￿:Move Enter:Select +/-/PU/PD:Value

F10:Save ESC:Exit

 

All Voltages

These items display the voltage of each element.

-Shutdown Enable

Use <Space> key to enable system shutdown function. If the voltage of corresponding element is higher/lower than the high/low limit, the system will automatically shutdown.

-Beep Enable

Use <Space> key to enable warning beeps function. If the voltage of corresponding element is higher/lower than the high/low limit, warning beeps will sound.

-High/Low Limit

These items set the high and low voltage limit.

The value of high limit must be set above the one of low limit.

3-6

AW9D-MAX, AW9D

Page 42
Image 42
Abit AW9D-MAX manual Voltage Monitoring