Adams Condensing Oil-Fired Furnace 1m ortant, Ii. Safety, Oil Pressure Gauge, Figure

Models: Condensing Oil-Fired Furnace

1 25
Download 25 pages 62.56 Kb
Page 3
Image 3
II. SAFETY

I. Component Identification

IGNITION TRANSFORMER ---- t -.......

FUEL PUMP --- t --- . ,

PRESSURE SWITCH

ITEM

DESCRIPTION

PART NO.

 

 

 

 

LETIER

 

 

 

 

 

 

 

A

FAN TIMER

CTVS24AA

 

 

 

 

B

TRANSFORMER

GH1033

 

 

C

BLOWER RELAY

M-3212

 

 

D

AlC RELAY

M-3212

 

 

E

BURNER RELAY

M-3212

 

 

F

24v TERMINAL STRIP

AGH1059

 

 

G

115v TERMINAL STRIP

AGH1059

 

 

H

BLOWER MOTOR TERMINAL BLOCK

EE8201

 

BLO'JER

 

 

 

 

 

 

 

 

SECTION

 

 

 

 

 

___-- . HIGH LIMIT

~_--PRIMARY OIL CONTROL

t . ---BURNER MOTOR

____-- FUEL FILTER HEAD

+---+--__FUEL FILTER CARTRIDGE

AUXILIARY UMIT

-----MANUAL RESET

---- CONDENSATE COLLECTOR

----BLOWER DOOR INTERLOCK SWITCH

II. SAFETY

Please adhere to the following warnings and cautions when installing, adjusting, altering, servicing, or operating the furnace.

1m ortant

The following Instruments must be used to adjust the burner on startup.

Failure to use the proper instruments will void our warranty and will result in an unsatisfactory instaUation.

BacharaCh Electronic Combustion Analyzer

Bacharach Smoke Tester

(Or equivalent to above)

Oil Pressure Gauge

!WARNING

TO PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE, REFER TO THIS MANUAL. FOR ADDITIONAL ASSISTANCE OR INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE FUEL OIL SUPPLIER.

Figure 1

!WARNING

HIGH VOLTAGEI

TO AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, THE FURNACE MUST BE LOCATED TO PROTECT THE ELECTRICAL COMPONENTS FROM WATER.

!WARNING

DO NOT UTILIZE THE HEATING UNIT WITHOUT REASONABLE ROUTINE INSPECTION, MAINTENANCE AND SUPERVISION. IF THE UNIT IS IN A BUILDING THAT IS OR WILL BE VACANT, CARE SHOULD BE TAKEN TO ROUTINELY INSPECT, MAINTAIN AND MONITOR THE UNIT. IN THE EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT, DRAIN ALL WATER­ BEARING PIPES, PROPERLY WINTERIZE THE BUILDING AND TURN OFF ALL WATER SOURCES. IN THE EVENT THAT THE BUILDING IS EXPOSED TO FREEZING TEMERATURES AND IS VACANT, ANY HYDRONIC COIL UNITS SHOULD ALSO BE DRAINED AND AN ALTERNATIVE HEAT SOURCE UTILIZED.