Chapter 9: Managing Logical Drives and Hot Spares
●
83
When the verification is complete, an event notice is generated in the
local system’s event log (and broadcast to other systems, if you have
event notification set up—see
).
You can now continue working on the controller.
Verifying a Logical Drive (Without Fix)
Note:
To verify and fix a logical drive, see
While Adaptec Storage Manager verifies a logical drive, you can’t
complete any other tasks on the controller associated with that logical
drive. Because verification takes a long time to complete, you may want
to schedule it as a task to be completed overnight or on a weekend.
To verify a logical drive:
1
In the Enterprise View, click the controller associated with the
logical drive.
2
In the Logical Devices View, click the logical drive.
3
In the menu bar, select
Actions
, then click
Verify
.
4
To begin the verification immediately, click
Yes
.
To schedule the verification for later, click
Schedule
, set the date and
time, then click
Apply
. You can also set the verification to recur. (For
Note:
Don’t power off the system while the verification is in
progress. If you do, the verification will stop.