Chapter 9: Managing Logical Drives and Hot Spares 88
4Select a new RAID level, then click Next. Only valid options are
offered.
In the example shown in this section, a RAID 1 logical device is
being changed to a RAID 5 logical device.
5In the Logical Devices panel, select the disk drives you want t o use in
the modified logical drive.
A daptec Storage Manager prompts you to select the correct number
of disk drives, as shown below.
If you want to remove a specific disk drive and replace it with
another one (for instance, replace a smaller disk drive with a larger
one), click on the disk driv e you want t o remo ve. An X indicat es that
the selected disk drive will be removed from the logical drive.
6Modify the Advanced Settings, if required. (See Fine-tuning Logical
Drives on page 78.)
Number of disk drives required