Monitoring System Activity and Performance LTPH-UM-1049-02, Issue 2
44 January 9, 2002 H2TU-C-319 List 4E
USING THE PERFORMANCE SCREENS TO VIEW ALARM DATA
To access the alarm history screens:
1Press to select the Performance menu.
2Press the to select an interface (H2TU-C DS1, H2TU-R DS1, H2TU-C HDSL2, or
H2TU-R HDSL2), then press .
3Press the until Alarm History is selected, then press .
Press or to page through the alarm history screens.
Press to clear the selected alarm history screen.
Alarm History at the DS1 Interface
The Alarm History screen reports DS1 statistics for the H2TU-C, shown in Figure25 below, and the H2TU-R,
shown in Figure 26 on page45, on a continuous basis. The types of alarms reported are described in Table 17 on
page 45. Current alarms are shown in reverse video.
Figure 25. H2TU-C DS1 Alarm History Screen
P
SPACEBAR
ENTER
SPACEBAR ENTER
N P
L
Monitor Performance Event Log Config Inventory Report Rlogon Help
H2TU-C DS-1 Alarm History
-----------------------------------------------------------------------------
Alarm First Last Status Count
SPTE OK 0
SPTF OK 0
LLOS OK 0
LAIS OK 0
DBER DISABLED 0
Press: C(l)ear Alarm History
------------------------------------------------------------------------------
Use <Space> to cycle through Interface : H2TU-C DS-1
choices and <Enter> to view Statistics : Alarm History
ID: xxxx--xxxx--xxxx--xxxx 08/01/2001 07:05:33 H2TU-C System: Alarm