LTPH-UM-1049-02, Issue 2 Testing
H2TU-C-319 List 4E January 9, 2002 63
5Once the test is complete, do one of the following:
If the system is to loopdown but remain Armed, send the IR (Intelligent Repeater) LPDN code for
universal loopdown.
If all the equipment is to be looped down, disarmed and returned to normal operation, send the disarm
in-band code 11100 or the ESF DL code (FF24).
The Time-out Override function is only valid for the current active loopback. The automatic
time-out timer is restored during subsequent loopback sessions.
The Armed mode has an automatic time-out of 120 minutes, but this timer is re set to 120 for any
of the following events:
Loopback terminates (manually or time-out)
Query
Alternate query
Far-End activate
Another ARM command
This timer is inhibited while any of the valid command codes are being sent. Once the codes
are removed, the timer restarts at 120.