In addition to the front panel Room 2 controls, the GTP-760 provides an interface for controlling Room 2 remotely. Such a connection is technically sophisticated and usually intended only for custom installations. Please contact your ADCOM dealer or ADCOM directly for further information on these advanced features and capabilities.

5.0 TROUBLE SHOOTING

Your GTP-760’s circuitry is built around advanced microprocessors. The GTP-760 may exhibit occasional anomalies arising from AC line surges, etc. If you experience unexpected behavior, or if the GTP-760 “locks up” and does not respond to control input, reset it by turning the front power switch off. (Do not use the remote control’s “power” button.) Wait 10 seconds and then turn the GTP-760 on. This will reset the internal control circuitry and solve most problems.

SYMPTOM

Power LED does not light

Power LED glows but no sound

No Video Output

No sound from one channel

Hum from all speakers (any volume)

Hum from all speakers (increases or decreases with change in system volume)

POSSIBLE REASON

POSSIBLE SOLUTION

AC Power Cord not plugged in

Plug in AC Power Cord

AC Fuse failed

Replace AC Fuse

Power amp or source unit is not ON

Make sure whole system is ON

Video Processor (rear panel) is ON

Move video processor switch to OFF

Connections in rear of amp are loose

Verify all connections on rear of amp

Input or Output connector

Verify both connections on that

disconnected or loose

channel

Speaker disconnected

Verify connection at speaker

Ground loop present

If cable TV is present, see Note 1

(difference in ground voltages

If cable TV is not present,

between components)

see Note 2

A major appliance, dimmer,

Make sure all appliances, dimmers

halogen or fluorescent light may be

and suspect lights are off

creating interference

 

Problem with source unit (CD, etc.)

Try different source to verify

Problem with cable connecting that

Try different cable to verify

source to the Tuner/pre-amp

 