Electrical specifications

Electrical specifications

1.All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. If you have any questions regarding the following instructions, contact a licenced electrician.

2.Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3.For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licenced electrician.

4.The wall outlet (3-pin) must match the plug

(3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information.

5.The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit. Make sure to use the correct power supply according to the rating plate of your air conditioner.

Electric Shock Hazard

!

If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker.

If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.

To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.

RECEPTACLE AND FUSE TYPES

COOLING CAPACITY

10K-12K

18K(Cooling only)

24K

18K-24K

(Cooling only)

10K-12K(With heating)

(Cooling only)

(With heating)

 

RATED VOLTS

125

250

250

250

 

 

 

 

 

AMPS

15

15

20

30

 

 

 

 

 

 

WALL OUTLET

 

 

 

 

FUSE SIZE

15

15

20

30

Table 1

Note:10K-12K(Cooling only) including models AAW-10CR1FHU AAW-10CM1FHU AAW-12CR1FHU AAW-12CM1FHU 18K(Cooling only) including models AAW-18CR3FHU AAW-18CM3FHU