Specifications
Physical Specifications
Dimensions | Base unit: | 367 mm x 240 mm x 106 mm |
|
| 14.45 in. x 9.45 in. x 4.17 in. |
| Remote Display: | 118 mm x 41 mm x 32 mm |
|
| 4.65 in. x 1.6 in. x 1.26 in. |
|
|
|
Weight | 5.7 kg (12.6 lbs) |
|
|
| |
AC input connections | Two | |
| No. 18 AWG (G) minimum 152 mm (6 in.) long in a separate | |
| AC wiring enclosure with 21.3 mm (0.84 in.) hole provision for | |
| connection of a ½ inch North American "trade size" cable clamp | |
| or conduit hub or international PG 13.5 or PG16 or M20 gland or | |
| cable strain relief fitting. | |
|
| |
DC output connections | Four | |
| negative) for battery cable ring terminals and one M6 mm DC | |
| equipment ground | |
|
|
|
Electrical Specifications
Number of battery bank outputs | 3 isolated, independently controlled outputs | ||||
|
|
|
|
|
|
Nominal battery voltage | 12 V units: | 12 | VDC |
|
|
| 24 V units: | 24 | VDC |
|
|
|
|
|
|
| |
Normal operating output range | 12 V units: | 0 – 16 VDC |
|
| |
| 24 V units: | 0 – 32 VDC |
|
| |
|
|
|
|
| |
Nominal operating AC voltage | 110 – 240 VAC |
|
|
| |
|
|
|
|
| |
Rated DC output current (total) | XC3012: | 30 | A (up to 15 V) |
| |
| XC5012: | 50 | A (up to 15 V) |
| |
| XC1524: | 15 | A (up to 30 V) |
| |
| XC2524: | 25 | A (up to 30 V) |
| |
|
|
|
|
| |
Absorption voltage (in VDC for |
| 50 °C (122 °F) | 25 °C (77 °F) | <0 °C (32 °F) | |
XC3012 and XC5012) | Flooded |
| 13.7 | 14.4 | 15.1 |
(Multiply VDC by 2 to get the | Gel |
| 13.5 | 14.2 | 14.9 |
absorption voltage for XC1524 | AGM |
| 13.8 | 14.3 | 14.8 |
and XC2524) | 14.8 | 15.5 | 16.0 | ||
|
|
|
|
|
|