Symbology Specifications

Symbology

Parameters (defaults are in bold)

EAN/UPC

Enable: On or off

 

Magnification factor: (080/085/090/100/105/110/115/120/130/140/150/

 

160/180/200)

 

Expand U.P.C.-EO: Yes or No

Code 39

Enable: On or off

 

Check Character: None or Checked

 

Fixed W/N: None or a value between 1.4 and 3.9 + 0.2

Interleaved

Fixed Msg Len*: None or a value between 1 and 49 characters

2 of 5

Enable: On or off

 

Check Digit: None or Checked

 

Fixed W/N: None or a value between 1.4 and 3.9 + 0.2

Code 128

Fixed Msg Len*: None or a value between 1 and 78 digits

 

Enable: On or off

Code 93

Modes Shown? Yes or No

 

Fixed Msg Len*: None or a value between 1 and 70 characters

 

Enable: On or off

Codabar

Fixed Msg Len*: None or a value between 1 and 80 characters (from

 

Code 39 set)

 

Enable: On or off

 

Character Font & Tolerances: Trad’l,”USS” or ISO/IEC’83

Code 11

Fixed W/N: None or a value between 1.4 and 3.9 + 0.2

 

Fixed Msg Len*: None or a value between 1 and 61 digits

 

Enable: On or off

 

1 or 2 check digits

 

Fixed Msg Len*: None or a value between 1 and 80 digits

Code 16K

Enable: On or Off

 

Modes Shown? Yes or No

 

Fixed Msg Len*: None or up to 154 characters, full symbol

Code 49

Enable: On or Off

 

Fixed Msg Len*: None or up to 49 alpha (81 numeric characters, full

 

symbol

MSI Code

Enable: On or Off

 

User Check: None, Mod 10 or Mod 11

 

Fixed Msg Len*: None or a value between 1 and 50 digits

IATA 2 of 5

Enable: Yes or No

Regular 2 of 5

Enable: Yes or No

 

Enable: Checked or None

 

 

*The message length specification for each symbology is listed. Although you can enter any value between 0 and 255, the unit does not decode more than the values indicated by the specification.

Quick Check® 600/800 Series User’s Guide

3 - 3

Page 27
Image 27
Hand Held Products 800, 600 manual Symbology Specifications, Symbology Parameters defaults are in bold