Using SSTR Codes to Review Data

A Single Scan to Result (SSTR) Code is a bar code symbol that tells the verifier to execute certain command functions. If you scan an SSTR Code, the unit displays the scan result parameter represented by that bar code symbol. After you scan a symbol, either the default results appear (listed below) or, if you changed the output display options, the results you specified appear.

 

SSTR Codes

SSTR Code Type and

Type

Test Criteria and

Name

Notes

 

 

 

 

Parameter SSTR Codes

 

 

Average Bar Error

Dim

traditional

W/N Ratio

Dim

traditional

Decodability

Dim

ISO/IEC

R(I) : R(d)

Ref

traditional and ISO/IEC

P.C.S.

Ref

traditional

Symbol Contrast

Ref

ISO/IEC

Rmin/Rmax

Ref

ISO/IEC

Modulation

Ref

ISO/IEC

Edge Contrast (Min)

Ref

ISO/IEC

Defects

Ref

ISO/IEC

Symbol Type

Fmt

traditional and ISO/IEC

Message Length

Fmt

traditional and ISO/IEC

Default

Dim/Ref

ISO/IEC Decodability &

 

 

Modulation traditional

 

 

Average Bar Error and

 

 

P.C.S.

Install Upper Line

installs upper result line

Install Lower Line

installs lower result line

Save Settings

saves settings

To review results that are not on the display, use the arrow buttons or simply scan one of the parameter SSTR codes for the type result you want. The result appears on the verifier’s lower display line. Use the arrow buttons to step through the verifier’s menus (Dim, Ref and Fmt) to view these results. Chapter 11, SSTR Codes includes a list of SSTR Codes.

Use the other SSTR Codes (Default, Install Upper Line, Install Lower Line and Save Settings) to customize your verifier.

If you want to review one or two parameter results after each scan, you can customize the verifier so these results appear as the default first screen. For example, if you are most interested in the message length and symbol contrast data, you can set your unit to display the message length and symbol contrast results automatically after each scan.

4 - 16

Quick Check® 600/800 Series User’s Guide

Page 60
Image 60
Hand Held Products 600, 800 manual Using Sstr Codes to Review Data, Sstr Code Type Test Criteria Name