Error Messages on Remote Display
975-0187-01-01 4–5
Red fault indicator light
illuminated
Green 10% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated
Battery Too
Cold
Shutdown
Allow batteries to warm up before
attempting to charge again. Ch argi n g a
battery that has frozen is a potential
explosion hazard.
25% current indicator light
flashes Battery
Disqualified
Warni ng
Wait 15 minutes for the next battery
detection cycle. The warning may be
temporary.
Verify that the ba tt ery me ets t he m ini mum
AmpHour rating (XC1524: 30Ah,
XC2524: 50Ah, XC3012: 60 Ah,
XC5012: 100Ah)
Try adding a small DC load.
Replace the battery.
Display green bank indicator
light for the affected battery
bank illuminated
Over Voltage
Shutdown
Warni ng
Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with el ec tr i c s t ar t.
If the warning level esca la tes without
being corrected, the X CS eries enter the
fault level and stop charging the affected
bank.
Red fault indicator light
illuminated
Display green bank indicator
light for the affected battery
bank illuminated
Over Voltage
Shutdown Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with el ec tr i c s t ar t.
Table 4-2
Error Messages
Display Onboard Status Panel
Indicator lights Fault Solution