Error Messages on Remote Display

 

 

 

 

Table 4-2Error Messages

 

 

 

 

Onboard Status Panel

 

 

 

 

 

 

Display

 

Indicator lights

Fault

Solution

 

 

 

 

 

Err

 

Red fault indicator light

Battery Too

Allow batteries to warm up before

 

illuminated

Cold

attempting to charge again. Charging a

CLd

 

 

Green 10% indicator light

Shutdown

battery that has frozen is a potential

 

 

 

 

flashes

 

explosion hazard.

 

 

Display green bank indicator

 

 

 

 

light for affected battery bank

 

 

 

 

illuminated

 

 

 

 

 

 

 

DIS

 

25% current indicator light

Battery

Wait 15 minutes for the next battery

 

flashes

Disqualified

bank.

 

 

detection cycle. The warning may be

 

 

 

Warning

temporary.

 

 

 

 

Verify that the battery meets the minimum

 

 

 

 

AmpHour rating (XC1524: 30 Ah,

 

 

 

 

XC2524: 50 Ah, XC3012: 60 Ah,

 

 

 

 

XC5012: 100 Ah)

 

 

 

 

Try adding a small DC load.

 

 

 

 

Replace the battery.

 

 

Display green bank indicator

Over Voltage

Check battery. Do not charge a battery

 

 

light for the affected battery

Shutdown

rated at more than 12 volts nominal

 

 

bank illuminated

Warning

(XC3012, XC5012) or 24 volts nominal

 

 

 

 

(XC1524, XC2524).

 

 

 

 

Disconnect or turn off other charging

 

 

 

 

sources such as the alternator or the

 

 

 

 

charger on a generator with electric start.

 

 

 

 

If the warning level escalates without

 

 

 

 

being corrected, the XC Series enter the

 

 

 

 

fault level and stop charging the affected

 

 

 

 

 

HI

 

Red fault indicator light

Over Voltage

Check battery. Do not charge a battery

 

illuminated

Shutdown

rated at more than 12 volts nominal

 

Display green bank indicator

 

(XC3012, XC5012) or 24 volts nominal

 

light for the affected battery

 

(XC1524, XC2524).

 

bank illuminated

 

Disconnect or turn off other charging

 

 

 

sources such as the alternator or the

 

 

 

charger on a generator with electric start.

975HIErr-0187

 

-01-01

 

4–5

 

 

Page 63
Image 63
Xantrex Technology XC1524, XC5012, XC2524, XC3012 manual Err